PH30 PH120 LPCB Fire Resistance Resistant Cable 2core

Product Details
Customization: Available
Application: Fire Alarm System Cable
Conductor Material: Tc/Bc
Still deciding? Get samples of US$ 0.05/Meter
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
>2000 square meters
  • PH30 PH120 LPCB Fire Resistance Resistant Cable 2core
  • PH30 PH120 LPCB Fire Resistance Resistant Cable 2core
  • PH30 PH120 LPCB Fire Resistance Resistant Cable 2core
  • PH30 PH120 LPCB Fire Resistance Resistant Cable 2core
  • PH30 PH120 LPCB Fire Resistance Resistant Cable 2core
  • PH30 PH120 LPCB Fire Resistance Resistant Cable 2core
Find Similar Products

Basic Info.

Model NO.
Fire Alarm Cable
Cover Material
PVC
Type
Fire Detection and Fire Alarm System
Material Shape
Round Wire
Conductor Type
Stranded
Wire Core Material
Bare Copper Wire
Certification
CE, RoHS, CCC, CPR
Model
2cores
Brand
Exactcables
Cable Core
2cores
Shield
Al/Foil
Drain Wire
1/0.5tc mm
Jacket
PVC
PH30
PH30 PH120 UL1424
Transport Package
Shipping Box or Wooden Pallet
Specification
2cores
Trademark
ExactCables
Origin
Ningbo
Production Capacity
5000000000

Packaging & Delivery

Package Size
10.00cm * 15.00cm * 10.00cm
Package Gross Weight
1.000kg

Product Description

 BS Standard LPCB Fire Resistant Cable

PH30 PH120 LPCB Fire Resistance Resistant Cable 2core


Applications:

LPCB approved fire resistant cable maintains circuit integrity under fire for a stated period of time and under defined conditions. With features of thermosetting insulation, resistance to fire, low smoke and low gas emissions, it ensures the maximum fire safety and fire evacuation capability.


Design                         BS 7629-1: 2008 Category STANDARD 30
                                         The complete cable shall have a duration of survival of ≥ 30 min when tested as BS EN                                                                          50200.



Fire resistance test    BS EN 50200:2006, class PH30 as 30 minutes to flame at 830°C and mechanical shocks.
                                          BS EN 50200 Annex E, 15 minutes to fire at 830°C and impact + additional 15 minutes of fire, impact
                                          and water spray.
                                          BS 5839-1: 2013, clause 26.2d, meet the class PH30 with EN50200.
 

Fire resistance test     BS 6387:2013 (Category CWZ)
                                          Category C, 3 hours to flame at 950°C.
                                          Category W, 15 minutes to flame at 650°C and further 15 minutes to flame and water spray.
                                          Category Z, 15 minutes to flame at 950°C with mechanical shocks each 30s.


Smoke emission test    BS EN 61034-2: 2005, the smoke generated shall result in transmittance values of not less than 80%.


Halogen emission test  EN 50267-2-1:1999, less than 0.5% HCI for the outer covering, binder tape & insulation when test.


Basic specification:

 
Certificate
LPCB approved
Standard
BS 7629-1: 2008, STANDARD 30
Operating temperature
-40°C to 200°C (ambient temp. 90°C)
Voltage rating
300V / 500V
Min bending radius
6 x Diameter
Packaging
Reel 500m, or customized
Feature
Sunlight resistant; Sequential footage marking every 1 meter
Application
  Primary for emergency lighting circuit, fire detection, fire alarm, voice alarm, etc.
 
                                 
PH30 PH120 LPCB Fire Resistance Resistant Cable 2core
·Conductor: 
Plain annealed copper, as BS EN 60228 Class 1
 
 
·Insulation:
Fire resistant silicone rubber, EI 2 type as BS
EN 50363-1
·Wrapping:Mica tape
 
·Screen/Shield:Aluminum foil, thickness ≥ 0.075mm
 
·Drain wire:Tinned copper, 1 x 0.8mm Diameter (0.50mm2)
 
·Outer Sheath:
LSZH (Low smoke zero halogen) thermoplastic
sheathing compound, LTS 3 type as BS 7655-6.1




 
Available size: 
 
Ref. No.
C04-2Cx1.0
C04-2Cx1.5
C04-2Cx2.5
Stranded / solid conductor         
Solid
Solid
Solid
Conductor size (mm)
1.13 1.35 1.7
Core NO. x Section (mm )
2 x 1.00
2 x 1.50
2 x 2.50
DC Resistance 20°C(Max,Ω/KM)
18.10
12.10 7.41
Insulation OD (mm)        
2.45 ± 0.1
2.60 ± 0.1
2.90 ± 0.1
Insulation THK (mm)
0.62 0.62 0.62
Insulation color
Brown / blue
Brown / blue
Brown / blue
Outer Sheath OD (mm)
6.60 ± 0.2
7.2 ± 0.2
7.80 ± 0.2
Outer Sheath THK (mm)
0.80 0.70 0.70
Outer Sheath color
Red
Red
Red
PH30 PH120 LPCB Fire Resistance Resistant Cable 2core
PH30 PH120 LPCB Fire Resistance Resistant Cable 2core
 
PH30 PH120 LPCB Fire Resistance Resistant Cable 2core
PH30 PH120 LPCB Fire Resistance Resistant Cable 2core
 
 

PH30 PH120 LPCB Fire Resistance Resistant Cable 2corePH30 PH120 LPCB Fire Resistance Resistant Cable 2corePH30 PH120 LPCB Fire Resistance Resistant Cable 2corePH30 PH120 LPCB Fire Resistance Resistant Cable 2core
QUALITY POLICY:

Exactcables will manufacture cable according to customer's requirement in an effective and profitable manner. To achieve the above, the Management is committed to the following:

 
  • Maintain the ISO 9001 Quality Management System
  • Continual review and improvement of the effectiveness of the Quality Management System
  • Provide all necessary resources to manufacture quality cable
  • Create a safe and technologically advanced working environment
  • Respect for the environment in which we operate
  • Training and communication to keep employees informed and involved
Every employee has the responsibility to ensure that these requirements are met.


 

FAQ:
Q1: What kind of cable do you produce?
A: We specialized in producing Fire alarm cables, Alarm/security cables, Speaker cables, Coaxial cables, Data cables, HDMI cables, telecommunication cables, telephone cables, power cables and other various of cables and wires
We also provide cable accessory products such as connector, cable clip,cable tie,crimping tool, antenna dishe,splitters,amplifer,optical receiver,optical transmitter etc

Q2: What's your MOQ? Can you offer free samples?
A: Our MOQ is 10KM per item. Free samples can be sent to you if available in stock,freight cost need to be paid by your side.

Q3: What's your delivery time?
A: Normally, our delivery time is 15 days after received deposit,it base on the quantity of the order.

Q4: What's your payment term?
A: We accept T/T, L/C,Western Union.Other payments accept through negotiation.

Q5:What's your trade term?
A: We accept FOB ShangHai or Ningbo,CFR,CIF,EXW term

Q6: Where is your factory located? How can I visit there?
A:Our factory is located in Ningbo City, Zhejiang Province, China, about 30 minutes away from Ningbo Lishe Airport .All our clients, from home or abroad, are warmly welcome to visit us!

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier