Still deciding? Get samples of $ !
Order Sample
|
| Customization: | Available |
|---|---|
| Application: | Fire Alarm System Cable |
| Conductor Material: | Tc/Bc |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Fire safety should not be taken lightly. Placing very high fire-safety preventive measures is important since it keeps people safe from danger and harm. It can also minimize the cost of damage recovery and prevent future costs due to possible lawsuits. It is also important to place a good effort in knowing what particular safety measures are needed to prevent fire-related accidents.
Fire alarm cables is one case as well. Since these cables are used for fire alarms and fire-preventive measures, these cables should be able to function while there is an ongoing fire. Installing regular wires may cause larger fires or worse can lead to accidents since these wires are not specially made for the situation. There are a lot of considerations needed especially if you want to ensure the proper installation of your fire alarm system in your establishment.
Luckily, Ningbo ExactCables Co., Ltd is here to help you with your fire-related equipment needs.

Fire alarm cables are a crucial component of any fire alarm system.
There are many uses for fire alarm cables, including smoke alarms, smoke detectors, voice communications, microprocessor-controlled systems, pull boxes for fire alarm signals, burglar alarms, and other low-voltage applications. Fire alarm circuits control and power various applications such as safety functions, elevator capture and shutdown, door release, and damper control.
We offer a variety of shielded and unshielded Plenum, Non-Plenum, and Riser fire alarm cables FPLP and FPLR, ranging from 18 AWG to 12 AWG solid bare copper conductors. These fire cables are flexible for easy installation. With our commitment to quality and dependability, our cables are UL, ETL listed, and RoHS compliant. Plenum-rated fire cables means it can be run in the area between floors that is used as duct area or other air space. Plenum refers to the material used in the jacket of the cable that burns less than non-plenum cables.
|
Conductor Size (no./mm) |
Drain Wire Size (no./mm) |
Cable Diameter mm (±5 %) |
Weight |
|
|
2×1.5 |
30/0.25 |
1/0.80 |
7.5 |
|
|
2×2.5 |
49/0.25 |
1/0.80 |
8.5 |
|
|
2×4.0 |
56/0.3 |
1/0.80 |
9.6 |
|
|
2×6.0 |
85/0.3 |
1/0.80 |
11.7 |
|
|
3×1.0 |
30/0.2 |
1/0.80 |
6.5 |
|
|
3×1.5 |
30/0.25 |
1/0.80 |
7.4 |
|
|
3×2.5 |
49/0.25 |
1/0.80 |
8.65 |
|
|
3×4.0 |
56/0.3 |
1/0.80 |
10.1 |
|
|
4×1.0 |
30/0.2 |
1/0.80 |
7.1 |
|
|
4×1.5 |
30/0.25 |
1/0.80 |
8.2 |
|
|
4×2.5 |
49/0.25 |
1/0.80 |
9.75 |
|
|
4×4.0 |
56/0.3 |
1/0.80 |
11.4 |
|
|
7×1.0 |
30/0.2 |
1/0.80 |
10.0 |
|
|
7×1.5 |
30/0.25 |
1/0.80 |
11.3 |
|
|
12×1.0 |
30/0.2 |
1/0.80 |
12.5 |
|
|
12×1.5 |
30/0.25 |
1/0.80 |
14.5 |
|
|
19×1.0 |
30/0.2 |
1/0.80 |
15.0 |
|
|
19×1.5 |
30/0.25 |
1/0.80 |
17.0 |
|
Fire alarm cables come in several types, each suited for specific applications. The main types of fire alarm cables include FPLR (Fire Power Limited Riser), FPLP (Fire Power Limited Plenum), and FPL (Fire Power Limited). Understanding these specifications helps you choose the right one for your system.
What Is FPLP Cable?
Fire power limited plenum (FPLP) fire alarm cables are plenum rated for horizontal overhead installations. Plenum cables can be installed in the plenum, which is where the name came from. You'll notice that plenum cables are much more expensive than riser cables because of the additional engineering and protection they offer. The plenum jacket is made from low-smoke plastics like PVC and limits fire spread throughout the ducting system. They're both offered in similar sizes because the amount of copper, or current, doesn't change when the insulation changes.
What Is FPLR Cable?
Fire power limited riser (FPLR) cable is the cheapest of the bunch because it's the most basic. When you don't need a shield or plenum insulation, you go with a riser fire alarm cable that gets installed vertically, hence the name "riser." These cables come in sizes 22 AWG through 12 AWG with two, four, six or eight possible conductors.
FPLR vs FPLP Fire Alarm Cable